Submit Manuscript  

Article Details


Comparison Between 18F-Dopa and 18F-Fet PET/CT in Patients with Suspicious Recurrent High Grade Glioma: A Literature Review and Our Experience

[ Vol. 12 , Issue. 3 ]

Author(s):

Laura Evangelista*, Lea Cuppari, Luisa Bellu, Daniele Bertin, Mario Caccese , Pasquale Reccia, Vittorina Zagonel and Giuseppe Lombardi   Pages 220 - 228 ( 9 )

Abstract:


Purposes: The aims of the present study were to: 1- critically assess the utility of L-3,4- dihydroxy-6-18Ffluoro-phenyl-alanine (18F-DOPA) and O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET) Positron Emission Tomography (PET)/Computed Tomography (CT) in patients with high grade glioma (HGG) and 2- describe the results of 18F-DOPA and 18F-FET PET/CT in a case series of patients with recurrent HGG.

Methods: We searched for studies using the following databases: PubMed, Web of Science and Scopus. The search terms were: glioma OR brain neoplasm and DOPA OR DOPA PET OR DOPA PET/CT and FET OR FET PET OR FET PET/CT. From a mono-institutional database, we retrospectively analyzed the 18F-DOPA and 18F-FET PET/CT of 29 patients (age: 56 ± 12 years) with suspicious for recurrent HGG. All patients underwent 18F-DOPA or 18F-FET PET/CT for a multidisciplinary decision. The final definition of recurrence was made by magnetic resonance imaging (MRI) and/or multidisciplinary decision, mainly based on the clinical data.

Results: Fifty-one articles were found, of which 49 were discarded, therefore 2 studies were finally selected. In both the studies, 18F-DOPA and 18F-FET as exchangeable in clinical practice particularly for HGG patients. From our institutional experience, in 29 patients, we found that sensitivity, specificity and accuracy of 18F-DOPA PET/CT in HGG were 100% (95% confidence interval- 95%CI - 81-100%), 63% (95%CI: 39-82%) and 62% (95%CI: 39-81%), respectively. 18F-FET PET/CT was true positive in 4 and true negative in 4 patients. Sensitivity, specificity and accuracy for 18F-FET PET/CT in HGG were 100%.

Conclusion: 18F-DOPA and 18F-FET PET/CT have a similar diagnostic accuracy in patients with recurrent HGG. However, 18F-DOPA PET/CT could be affected by inflammation conditions (false positive) that can alter the final results. Large comparative trials are warranted in order to better understand the utility of 18F-DOPA or 18F-FET PET/CT in patients with HGG.

Keywords:

DOPA PET/CT, FET PET/CT, gliomas, accuracy, systematic review, 18F-Dopa, 18F-Fet.

Affiliation:

Nuclear Medicine Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Nuclear Medicine Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Radiation Oncology Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Nuclear Medicine Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Oncology 1 Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Nuclear Medicine Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Oncology 1 Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Oncology 1 Unit, Veneto Institute of Oncology IOV - IRCCS, Padua

Graphical Abstract:



Read Full-Text article